Emerald Spa DS-4 Bedienerhandbuch Seite 19

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 33
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 18
DS series Instructions manual
16
7. FUNCTIONING MODE
The DS3 light grid is a detection and measurement device and thus the
beam interruption due to an object causes the switching of the digital
output (PNP type) and/or the change of the analog output signal. Small
objects (up to 0.5 mm), transparent films and measurement of
geometrical dimensions with a 6 mm resolution, can be obtained by
setting the device at the right sensitivity.
The different functioning modes available are listed below:
7.1. Scanning mode (see functions 1 and 2 of Tab.1 at page 14)
Two different scanning types can be accomplished with the
AREAscan
TM
of the DS3 series:
Scanning with PARALLEL beams: where each si ngl e
photoreceiver is illuminated only by the beam of the corresponding
photoemitter with a precise scanning sequence (this mode
activates only one photoreceiver/photoemitter couple each time,
during the scanning cycle).
This mode can be used both for the detection of objects as well as
the dimensional measurement (this measurement is supplied to the
operator by the analog output 0-10V). The minimum object that can
be detected has to be 6 mm (that represents the minimum
resolution (R), Fig.8, of the device in this mode).
Fig. 8
Seitenansicht 18