DS series Instructions manual
2
Some parts or paragraphs of this manual containing important
information for the operator are preceded by a note:
Notes and detailed descriptions about particular characteristics of the
AREAscan
TM
devices in order to better explain their functioning.
DATASENSOR technical assistance is available for any necessary
information related to the functioning and/or installation of the DS3
series light grids (see section 9 “Checks and periodical maintenance”).
1.2. Selecting the device
The choice of the device may be based on the following:
- detection area needed. This is the height of the device’s sensitive
zone
- maximum operating distance. This is the distance between the
emitter unit (TX) and receiver unit (RX)
Four versions are available:
Operating distance Detection field
DS3-SD-015
0.2 … 0.6 m 24 beams; h=150 mm
DS3-SD-030
0.2 … 0.6 m 48 beams; h=300 mm
DS3-LD-015
0.6 … 1.5 m 24 beams; h=150 mm
DS3-LD-030
0.6 … 1.5 m 48 beams; h=300 mm
The functions that characterise the DS3 AREAscan
TM
light grids are
available on all 4 versions that consequently have the same operating
modes.
The specific technical characteristics (e.g. resolution, sensitivity etc)
remain the same for all the versions, until differently indicated.
For food industry applications, please verify with DATASENSOR
Technical Service the compatibility of the materials of the light grid
shell with the eventual chemical agents that are used in the production
process.