Inhaltsverzeichnis

Seite 1 - INSTRUCTION MANUAL

DS3 SERIES Object detection and measurement light grid INSTRUCTION MANUAL

Seite 2 - UNI EN ISO 1 400

Instructions manual DS series 7 It is thus important to position the light grid according to the minimum distance from any reflecting sur

Seite 3

DS series Instructions manual 8 NO YES YES 2.2.3. Installation of several adjacent light grids When several devices must be installed in

Seite 4 - 1. GENERAL INFORMATION

Instructions manual DS series 9 Fig. 3 3. MECHANICAL MOUNTING The emitting and receiving bars must be installed with the relevant sens

Seite 5 - 1.2. Selecting the device

DS series Instructions manual 10 4. ELECTRICAL CONNECTIONS The electrical connection between the emitter and receiver units is made through

Seite 6 - 1.3. Typical applications

Instructions manual DS series 11 4.1. Notes on the connections For the correct functioning of the AREAscanTM . light grid, the following

Seite 7 - 2 INSTALLATION MODE

DS series Instructions manual 12 • The AREAscanTM are NOT safety devices and so MUST NOT be used to control the safety of the machines wh

Seite 8

Instructions manual DS series 13 5. FUNCTION SELECTION The functions implemented in the AREAscanTM devices can be selected using the dip-

Seite 9

DS series Instructions manual 14 Table 1 indicates the type of function and the relative position of the dip-switches. Tab. 1 NOTE: The d

Seite 10

Instructions manual DS series 15 6. CALIBRATION PROCEDURE The calibration procedure sets the signal level that arrives from the receiver

Seite 11

DS series Instructions manual 16 7. FUNCTIONING MODE The DS3 light grid is a detection and measurement device and thus the beam interru

Seite 12 - 3. MECHANICAL MOUNTING

DATASENSOR S.p.A. Via Lavino 265 4005 0 Monte S. Pietro - Bolog na - Italy Tel: + 39 051 676 561 1 Fax: + 39 051 6759 3

Seite 13

Instructions manual DS series 17 • Scanning with CROSSED beams: where several photoreceivers are illuminated by the beam of a single ph

Seite 14

DS series Instructions manual 18 7.2. Measurement mode 7.2.1. Absolute mode (see functions 5 and 6 of Tab.1 at page 14) Provides the measur

Seite 15

Instructions manual DS series 19 7.2.2. Relative measurement (see function 7 of Tab.1 at page 14) Provides the measurement of the dimensi

Seite 16 - 5. FUNCTION SELECTION

DS series Instructions manual 20 7.3. Detection mode (teach-in) The teach-in mode can be selected using the dip-switches (see functions 9

Seite 17

Instructions manual DS series 21 The following operating modes can be selected using the dip-switches: 7.3.1. Absolute detection (see fun

Seite 18 - 6. CALIBRATION PROCEDURE

DS series Instructions manual 22 7.3.2. Relative detection (see function 10 of Tab.1 at page 14) The digital output (PNP) switches each tim

Seite 19 - 7. FUNCTIONING MODE

Instructions manual DS series 23 7.4. DARK/LIGHT mode of the output ( see functio n 1 3 and 1 4 of Tab .1 at pag e 14) Defines th

Seite 20

DS series Instructions manual 24 8. DIAGNOSTIC FUNCTIONS 8.1. Visualisation of the device status The operator can verify the operating sta

Seite 21 - 7.2. Measurement mode

Instructions manual DS series 25 8.2. Fault and diagnostic messages The operator can verify the device functioning status and the stop o

Seite 22 - Analog output PNP output

DS series Instructions manual 26 8.2.2. Error mode RECEIVER UNIT Signal Cause Check and Repai r - PNP output does not switch. - Devic

Seite 23

DS series Instructions manual INDEX 1. GENERAL INFORMATION ...

Seite 24

Instructions manual DS series 27 9. CHECKS AND P ERIODICAL MAINTENANCE The following is a list of recommended check and maintenance oper

Seite 25

DS series Instructions manual 28 10. TECHNICAL DATA Po wer su ppl y: 24 V dc ± 15% Consu mpti on of emit ter u nit (TX): 100 mA m a

Seite 26 - ÷18 of Tab.1 at page 14)

Instructions manual DS series 29 11. LIST OF AV AILABLE M ODELS Model Length of sensitiv e area Length of controlled area N°. beams Re

Seite 27 - 8. DIAGNOSTIC FUNCTIONS

DS series Instructions manual 30 12. OVERALL DIM ENS IO NS All the dimensions given are in mm. RECEIVER EMITTER

Seite 28 - Signal Cause Check

Instructions manual DS series 1 1. GENERAL INFORMATION 1.1. General description of the AREAscanTM light g ri d The AREAscanTM light gr

Seite 29 - - Align the device again and

DS series Instructions manual 2 Some parts or paragraphs of this manual containing important information for the operator are preceded by a

Seite 30

Instructions manual DS series 3 1.3. Typical applications The following images supply an overview on some of the main applications. Ob

Seite 31 - 10. TECHNICAL DATA

DS series Instructions manual 4 2 INSTALLATION MODE 2.1. Precautions to be observed for the choice and installation of the device • The d

Seite 32 - MODEL a x b (mm) h (mm)

Instructions manual DS series 5 2.2. General information on the device positioning • Place the device near the detection area. • Ali

Seite 33

DS series Instructions manual 6 2.2.2. Minimum distance from reflecting surfaces Reflecting surfaces placed near the light beams of the A